When Handling Refrigerant
| 1.
|
R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in
localized
frostbite. When handling the refrigerant, be sure to wear gloves.
|
| 2.
|
It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect
your
hands. If the refrigerant splashes into your eyes, wash them with clean water immediately.
|
| 3.
|
The R-134a container is highly pressurized. Never leave it in a hot place, and check storage
temperature
is below 52°C (126°F).
|
| 4.
|
An electronic leak detector should be used to check the system for refrigerant leakage. Bear in
mind that
the R-134a, upon coming into contact with flame, produces phosgene, a highly toxic gas.
|
| 5.
|
Use only recommended lubricant for R-134a systems. If lubricants other than the recommended one
used,
system failure may occur.
|
| 6.
|
PAG lubricant absorbs moisture from the atmosphere at a rapid rate, therefore the following
precautions
must be observed :
|
•
|
When removing refrigerant components from a vehicle, cap the components
immediately to prevent
entry of moisture.
|
|
•
|
When installing refrigerant components to a vehicle, do not remove the cap
until just before
connecting the components.
|
|
•
|
Complete the connection of all refrigerant tubes and hoses without delay to
prevent the A/C
system from taking on moisture.
|
|
•
|
Use the recommended lubricant from a sealed container only.
|
|
| 7.
|
If an accidental discharge in the system occurs, ventilate the work area before resume of
service.
|
When Replacing Parts On A/C System
| 1.
|
Never open or remove a connection before discharging the system.
|
| 2.
|
Seal the open fittings of components with a cap or plug immediately to prevent intrusion of
moisture or
dust.
|
| 3.
|
Do not remove the sealing caps from a Replacement component until it is ready to be installed.
|
| 4.
|
Before connecting an open fitting, always install a new sealing ring. Coat the fitting and seal
with
refrigerant oil before making the connection.
|
When Installing Connecting Parts
Check the new O-ring for damage (use only the specified) and lubricate by using compressor oil. Tighten the nut
to specified torque.
| Handling Tubing And Fittings |
The internal parts of the refrigeration system will remain in a state of chemical stability as long as pure
moisture-free refrigerant and refrigerant oil are used. Abnormal amounts of dirt, moisture or air can upset the
chemical stability and cause problems or serious damage.
| The Following Precautions Must Be Observed |
| 1.
|
When it is necessary to open the refrigeration system, have everything you will need to service
the
system ready so the system will not be left open any longer than necessary.
|
| 2.
|
Cap or plug all lines and fittings as soon as they are opened to prevent the entrance of dirt
and
moisture.
|
| 3.
|
All lines and components in parts stock should be capped or sealed until they are ready to be
used.
|
| 4.
|
Never attempt to rebind formed lines to fit. Use the correct line for the installation you are
servicing.
|
| 5.
|
All tools, including the refrigerant dispensing manifold, the gauge set manifold and test
hoses, should
be kept clean and dry.
|
| 6.
|
Carefully inspect refrigerant connections, joint seals and seal surfaces for signs of wear,
deformation,
contamination or damage after disassembly. Prior to disassembly, look for presence of
refrigerant oil on
adjacent surfaces that could be sign of a leak.
|
| 7.
|
Never reuse seals / O-rings, but replace with all new parts.
|
| 8.
|
Ensure proper alignment of male/female portions and seal so there is no misalignment and stress
on the
fitting connection.
|
|
•
|
The R-1234yf liquid refrigerant is a flammable gas. The gas reduces oxygen
available for
breathing and causes asphyxiation in high concentrations. The victim will not
realize that he/she is
suffocating.
|
|
•
|
Inhalation may cause central nervous system effects and may cause drowsiness
and dizziness.
|
|
•
|
Ingestion may cause gastrointestinal discomfort. It may cause skin irritation,
eye irritation and
respiratory tract irritation. Do not breathe vapor. Avoid contact with skin,
eyes and clothing.
|
|
•
|
Un-controlled release of R-1234yf refrigerant in the work area may result in
high concentrations
of R-1234yf that can be flammable. Servicing of R-1234yf systems shall only be
done in well
ventilated work areas.
|
|
•
|
When servicing, maintaining or repairing A/C systems using flammable
refrigerants (mildly
flammable or higher) the work place shall meet all applicable national, regional
or local
regulations for work place safety as related to high pressure or flammable
gases.
|
|
|
•
|
In case of emergency, the following precautions must be observed : First
responders needs to
protect the themselves. Take off all contaminated clothing immediately.
|
|
–
|
Inhalation : Move to fresh air. If not breathing, give artificial respiration.
If breathing is
difficult, give oxygen. Use oxygen as required, provided a qualified operator is
present. Call a
physician.
|
|
–
|
Skin contact : After contact with skin, wash immediately with plenty of water.
Rapid evaporation
of the liquid may cause frostbite. If there is evidence of frostbite, bathe (do
not rub) with
lukewarm (not hot) water. If water is not available, cover with a clean, soft
cloth or similar
covering. Call a physician. Wash contaminated clothing before re-use.
|
|
–
|
Eye contact : Rinse immediately with plenty of water, also under the eyelids,
for at least 15
minutes. In case of frostbite water should be lukewarm, not hot. Call a
physician.
|
|
–
|
Ingestion : Unlikely route of exposure. As this product is a gas, refer to the
inhalation
section. Do not induce vomiting without medical advice. If conscious, drink
plenty of water. Never
give anything by mouth to an unconscious person. Call a physician immediately.
|
|
•
|
When handling the refrigerant, the following precautions must be observed;
|
|
–
|
Wear personal protective equipment.
|
|
–
|
Avoid contact with skin, eyes and clothing.
|
|
–
|
Ensure that eyewash stations and safety showers are close to the workstation
location.
|
|
–
|
Use only in well-ventilated areas.
|
|
–
|
Protect from sunlight and do not expose to temperatures exceeding 52 °C (125
°F).
|
|
–
|
Follow all standard safety precautions for handling and use of compressed gas
cylinders.
|
|
–
|
Use authorized cylinders only.
|
|
–
|
Protect cylinders from physical damage.
|
|
–
|
Do not puncture or drop cylinders, expose them to open flame or excessive heat.
|
|
–
|
Do not remove screw cap until immediately ready for use.
|
|
–
|
Always replace cap after use.
|
|
–
|
Container is hazardous when empty.
|
|
–
|
Prevent the creation of flammable or explosive concentrations of vapor in air
and avoid vapor
concentration higher than the occupational exposure limits.
|
|
–
|
Keep product and empty container away from heat and sources of ignition.
|
|
–
|
Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers
to heat or sources
of ignition.
|
|
–
|
Take measures to prevent the build up of electrostatic charge.
|
|
–
|
Electrical equipment should be protected to the appropriate standard.
|
|
–
|
Use explosion-proof equipment.
|
|
–
|
No sparking tools should be used.
|
|
•
|
When storing the refrigerant, the following precautions must be observed.
|
|
–
|
Pressurized container. Protect from sunlight and do not expose to temperatures
exceeding 52 °C
(125 °F). Do not pierce or burn, even after use.
|
|
–
|
Keep containers tightly closed in a dry, cool and well-ventilated place.
|
|
–
|
Keep away from heat and sources of ignition.
|
|
–
|
Storage rooms must be properly ventilated.
|
|
–
|
Ensure adequate ventilation, especially in confined areas.
|
|
–
|
Protect cylinders from physical damage.
|
|
–
|
Store away from incompatible substances.
|
|
–
|
Store in original container.
|
|
•
|
Avoid breathing any refrigerant vapor and lubricant mist. To remove refrigerant
from a A/C
system, use service equipment designed for recovery and removal that is
certified to meet the
requirements of the appropriate SAE standards.
|
|
•
|
Do not increase pressure, in any R-134a, or R-1234yf mobile A/C system with
shop air or another
refrigerant such as HCFC-22 (R-22) for leak checking, due to potential chemical
reactions,
flammability of air / R-134a at elevated pressure, contamination of the system,
and possible
structural damage to the system.
|
|
•
|
To prevent an accumulation of refrigerant in case of a major refrigerant leak,
open vehicle
windows and doors when charging an A/C system
|
|
•
|
To prevent accidental release of refrigerant and minimize safety concerns, the
installation of
any refrigerant service equipment to the vehicle shall only be done with the
turn off and after the
refrigerant high side pressure has been reduced (approximately 2 to 3 min).
|
|
•
|
Proper handling procedures should be followed for all refrigerants as
designated by the
refrigerant manufacturer’s Material Safety Data Sheet (MSDS).
|
|
•
|
Service personnel shall be aware of the high pressure relief valve location
when servicing the
vehicle. Service personnel shall not be under the vehicle when charging the
refrigerant system due
to potential sudden release of the high pressure relief valve.
|
|
When Handling Refrigerant
|
•
|
Some of the practices, techniques and procedures, as well as the information,
tools and equipment
which have been commonly used in mobile air conditioning system diagnosis and
service of R-12 and
R-134a are different for A/C systems using R-1234yf.
Modifications and adjustments have to be made based on the individual
characteristics of each
refrigerant. No technician may perform service or repair on a mobile air
conditioning system using
R-1234yf without being trained for the refrigerant being handled. Under the SAE
Standard J2845 the
refrigerant system should only be serviced by trained and certified technicians
to insure proper and
safe operation.
|
|
•
|
Service technicians should always wear proper personal protective equipment
while handling /
servicing systems that contain any refrigerant.
|
|
•
|
Service technicians shall read and follow the appropriate Material Safety Data
Sheets (MSDS),
which provide information on safety and the proper personal protective equipment
to use.
- All contact with liquid or gaseous refrigerant shall be avoided.
- Goggles with side protection and gloves (insulated against heat loss and
impermeable to
refrigerant) shall be worn while working with the refrigerant circuit.
- Exposure of the skin to refrigerant may result in frostbite, in which case
rub affected area
with lukewarm water. A physician shall be consulted immediately regarding the
affected skin areas.
|
|
•
|
A physician shall be consulted immediately in the event of complaints following
exposure to high
refrigerant concentrations. Complaint symptoms may include: increased breathing
rate,
breathlessness, headache, accelerated pulse, dizziness.
|
|
•
|
Avoid breathing A/C refrigerant and lubricant vapor or mist. To remove
refrigerant from the A/C
system, use service equipment designed for recovery of that refrigerant which is
certified to meet
the requirements of the appropriate SAE Standards.
|
|
| 1.
|
R-1234yf liquid refrigerant is highly volatile. A drop on the skin of your hand could result in
localized
frostbite. When handling the refrigerant, be sure to wear gloves.
|
| 2.
|
It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect
your
hands. If the refrigerant splashes into your eyes, wash them with clean water immediately.
|
| 3.
|
The R-1234yf container is highly pressurized. Never leave it in a hot place, and check storage
temperature is below 52 °C (125 °F).
|
| 4.
|
An electronic leak detector should be used to check the system for refrigerant leakage. Bear in
mind that
the R-1234yf, upon coming into contact with flame, produces phosgene, a highly toxic gas.
|
| 5.
|
Use only recommended lubricant for R-1234yf systems. If lubricants other than the recommended
one used,
system failure may occur.
|
| 6.
|
PAG lubricant absorbs moisture from the atmosphere at a rapid rate, therefore the following
precautions
must be observed:
|
•
|
When removing refrigerant components from a vehicle, cap the components
immediately to prevent
entry of moisture.
|
|
•
|
When installing refrigerant components to a vehicle, do not remove the cap
until just before
connecting the components.
|
|
•
|
Complete the connection of all refrigerant tubes and hoses without delay to
prevent the A/C
system from taking on moisture.
|
|
•
|
Use the recommended lubricant from a sealed container only.
|
|
| 7.
|
If an accidental discharge in the system occurs, ventilate the work area before resume of
service.
|
| 8.
|
Clean all dirt, grease and debris from and around connection joints before servicing and
disassembly of
refrigerant connections.
|
When Replacing Parts On A/C System
| 1.
|
Never open or remove a connection before discharging the system.
|
| 2.
|
Seal the open fittings of components with a cap or plug immediately to prevent intrusion of
moisture or
dust.
|
| 3.
|
Do not remove the sealing caps from a replacement component until it is ready to be installed.
|
| 4.
|
Before connecting an open fitting, always install a new sealing ring. Coat the fitting and seal
with
refrigerant oil before making the connection.
|
| 5.
|
The air conditioning evaporator (cooling coil) shall never be repaired or replaced with one
removed from
a used or salvaged vehicle and that new replacement A/C evaporators shall be certified (and
labeled) as
meeting SAE Standard J2842.
|
| 6.
|
In the case of all vehicles being serviced and identified as having a leaking evaporator, the
leak shall
not be repaired and the system shall only be serviced by replacing the leaking evaporator with a
new
evaporator meeting SAE J2842 requirements. An evaporator from a salvaged vehicle air
conditioning system
shall not be repaired or removed from any vehicle air conditioning system with the intention of
using it
again in the same or a different vehicle. However, if the evaporator assembly includes a
refrigerant control
device (TXV / Block valve) and is operational, re-use of the refrigerant control device is
permitted.
|
When Installing Connecting Parts
Check the new O-ring for damage (use only the specified) and lubricate by using compressor oil. Tighten the nut
to specified torque.
| Handling Tubing And Fittings |
The internal parts of the refrigeration system will remain in a state of chemical stability as long as pure
moisture-free refrigerant and refrigerant oil are used. Abnormal amounts of dirt, moisture or air can upset the
chemical stability and cause problems or serious damage.
| The Following Precautions Must Be Observed |
| 1.
|
When it is necessary to open the refrigeration system, have everything you will need to service
the
system ready so the system will not be left open any longer than necessary.
|
| 2.
|
Cap or plug all lines and fittings as soon as they are opened to prevent the entrance of dirt
and
moisture.
|
| 3.
|
All lines and components in parts stock should be capped or sealed until they are ready to be
used.
|
| 4.
|
Never attempt to rebind formed lines to fit. Use the correct line for the installation you are
servicing.
|
| 5.
|
All tools, including the refrigerant dispensing manifold, the gauge set manifold and test
hoses, should
be kept clean and dry.
|
| 6.
|
Carefully inspect refrigerant connections, joint seals and seal surfaces for signs of wear,
deformation,
contamination or damage after disassembly. Prior to disassembly, look for presence of
refrigerant oil on
adjacent surfaces that could be sign of a leak.
|
| 7.
|
Never reuse seals / O-rings, but replace with all new parts.
|
| 8.
|
Ensure proper alignment of male/female portions and seal so there is no misalignment and stress
on the
fitting connection.
|
Other information:
Kia K4 (CL4) 2025-2026 Service Manual: Inside rearview mirror
Adjust the inside rearview mirror so that you can view the entire rear window clearly from your driving position. Ensure this adjustment is finalized before you begin your journey in the Kia K4.
To maintain a clear view, avoid placing bulky items, boxes, or passengers in the rear seat or cargo area that could obstruct the rear window visibility.
WARNING
Mirror adjustment
For your safety, never attempt to adjust the rearview mirror while the Kia K4 is in motion.
Kia K4 (CL4) 2025-2026 Service Manual: Vehicle load limit
Understanding your Kia K4 vehicle load limit is essential for maintaining safety, handling performance, and fuel efficiency. You can find the specific load capacity details for your Kia K4 on the Tire and Loading Information label located on the driver-side door sill.
Tire and loading information label
This label provides critical data, including the original factory tire size, the recommended cold tire inflation pressures for your Kia K4, the maximum number of occupants allowed, and the total vehicle capacity weight.