Battery Visual and Basic Inspection
| 1.
|
Check the battery terminal corrosion and connection.
|
| 2.
|
Check the battery leakage or swelling.
|
| 3.
|
Check the case for damage.
|
Alternator Charging Current Inspection
| 1.
|
Check the alternator charging current.
(Refer to Charging System - "Alternator")
|
Vehicle Parasitic Current Inspection
[Using an Ammeter]
| 1.
|
Turn all electric devices OFF, and then turn the IG OFF.
|
| 2.
|
Close all doors except the engine hood, and then lock all doors.
|
–
|
Disconnect the connector from the hood switch to prevent it from being
operated.
|
|
| 3.
|
Wait until the main system of the vehicle goes into sleep mode.
|
For an accurate measurement of a vehicle parasitic current, all electrical
systems should go to
sleep mode. (It takes at least one hour or at most one day.) However, an
approximate vehicle
parasitic current can be measured after 10 - 20 minutes.
|
|
| 4.
|
Connect an ammeter between the battery negative ( - ) terminal and the negative ( - ) cable
terminal, and
then disconnect the battery cable ( - ) terminal slowly.
|
•
|
Be careful not to let the lead wire of the ammeter come off the
battery terminal and the
cable so that the battery is not initialized.
|
|
•
|
If the battery is initialized due to disconnection of lead wire
of ammeter from the
battery cable or terminal, reconnect the battery and start the
engine, or measure from the
first step after the IG is on for more than 10 seconds.
|
|
•
|
To prevent battery initialization in advance, follow the
procedure below.
|
| 1) |
Connect the jumper cable between the battery ( - ) terminal and
the cable ( - ) terminal
first.
|
| 2) |
Disconnect the negative ( - ) battery terminal.
|
| 3) |
Connect the ammeter in parallel to the jumper cable.
|
| 4) |
Disconnect the jumper cable and check the parasitic current
value of the ammeter.
|
|
|
| 5.
|
Check the parasitic current value of the ammeter.
|
•
|
If the parasitic current exceeds the limit value, remove the fuse one by one
and measure it to
find the problem circuit.
|
|
•
|
Re-measure the parasitic current and find the problem unit by removing the
units connected to the
problem circuit one by one.
|
Limit value (mA) : Below
50 (after 10 - 20 min.)
|
|
|
[[Using the Clamp Type Ammeter]
| 1.
|
Turn all electric devices OFF, and then turn the IG OFF.
|
| 2.
|
Close all doors except the engine hood, and then lock all doors.
|
–
|
Disconnect the connector from the hood switch to prevent it from being
operated.
|
|
| 3.
|
Wait until the main system of the vehicle goes into sleep mode.
|
For an accurate measurement of a vehicle parasitic current, all electrical
systems should go to
sleep mode. (It takes at least one hour or at most one day.) However, an
approximate vehicle
parasitic current can be measured after 10 - 20 minutes.
|
|
| 4.
|
Install the clamp type ammeter on battery negative ( - ) terminal
|
•
|
When using a clamp type ammeter, use an ammeter that can
measure mA. If not, it is
difficult to measure the correct parasitic current.
|
|
•
|
When ( - ) sign appears on the ammeter of the clamp type,
install the ammeter in the
opposite direction.
|
|
|
| 5.
|
Check the parasitic current value of the ammeter.
|
•
|
If the parasitic current exceeds the limit value, remove the fuse one by one
and measure it to
find the problem circuit.
|
|
•
|
Re-measure the parasitic current and find the problem unit by removing the
units connected to the
problem circuit one by one.
|
Limit value (mA) : Below
50 (after 10 - 20 min.)
|
|
|
Battery Performance Inspection
| 1.
|
Measure the performance of the battery by using the battery tester and battery load tester.
|
•
|
Check that the battery positive ( + ) and negative ( - )
terminals are properly
connected.
|
|
•
|
Do not disconnect the battery while the engine is running.
|
|
|
Battery Voltage Inspection
| 1.
|
If it is within 20 minutes since the engine is stopped, turn on the ignition switch and operate
the
electric devices (headlamp, blower motor, rear defogger) for 60 seconds to get rid of residual
voltage.
|
| 3.
|
Measure the voltage between the negative ( - ) terminal and battery positive ( + ) terminal of
the
battery.
|
Specified voltage (V) : approximately
12.5 - 12.9 [20°C
(68°F)]
|
|
| 4.
|
If the measured value is below the specified voltage, charge the battery.
|
AGM Battery Charging
Follow the charging method(DIN 41772) defined by German Standards Association (DIN).
|
–
|
I (Constant current) : It is also called
the constant
current method. this method is charging by maintaining regularly the current
from start the charging
to complete.
|
|
–
|
U(Constant voltage) : It is also called
the constant
voltage method. this method is charging by maintaining regularly the voltage
from start the charging
to complete.
|
|
–
|
W(Taper current) : It is called also the
single current
method. this method is a type of constant current method, and is charging by
decreasing the current
in charging step by step.
|
|
| 1.
|
Check the state of charge of the battery, and charge the battery if required.
|
How to charge IU or WU
IU or WU charging voltage (V) :14.7 [20 - 30°C (68 - 86°F)] Approximately 24
hours
Minimum charging voltage (V) : 14.4 [20°C (68°F)]
Maximum charging voltage (V) : 14.8 [20°C (68°F)]
A capacity of 10% of the charging current is recommended (e.g. 80 Ah : 100% =
8.0 A of charging
current)
|
|
|
•
|
Do not charge over the 15.2 V, and not quick charge.
|
|
•
|
Do not open or remove the cap on the top of the AGM battery.
|
|
•
|
Since explosive gas is formed in each cell when charging the battery, any
actions that may cause
ignition such as fire, sparks, light rays, smoking, etc. during or immediately
after charging the
battery are prohibited.
|
|
•
|
Do not open the circuit while the battery is charging as it will generate the
spark, keep away
from nearby flammable material.
|
|
|
•
|
The temperature of the battery shall be maintained at approximately 20 - 30°C
(68 - 86°F) during
charging.
|
|
•
|
If the battery sensor is charged while connected to the battery, the sensor may
not accurately
detect the state of the battery. Therefore, when the battery is fully charged,
use it after about 10
hours (stabilizing time of the battery) at room temperature. Otherwise, it will
result in a fault
code or the Alternator Management System (AMS) function may not work.
|
|
Other information:
Kia K4 (CL4) 2025-2026 Service Manual: Rear occupant alert (ROA) system
The advanced Rear Occupant Alert (ROA) system integrated into your vehicle is a vital driver assistance feature configured to monitor the rear passenger cabin. This sub-system actively reduces the risk of a child, infant, vulnerable passenger, or family pet being inadvertently left behind in the vehicle when the driver exits.
Environmental Sensor Optimization Protocol: To ensure the underlying ultrasonic interior sensors function with maximum accuracy, make sure that all side passenger windows and the sunroof assembly are completely closed whenever the ROA framework is operational.
Kia K4 (CL4) 2025-2026 Service Manual: Blind-Spot Collision-Avoidance Assist (BCA):
The Blind-Spot Collision-Avoidance Assist (BCA) system is designed to detect vehicles approaching in your blind spots and alert you to potential hazards using both visual and audible warnings. If the system calculates a high risk of collision during an intended lane change, the Kia K4 can provide supplemental braking assistance to help you avoid an accident.